P38412-B21 HPE ProLiant DL385 Gen10 Plus v2 24SFF Configure-to-order Server
Processor: AMD EPYC 7713 2.0GHz 64-core 225W Processor for HPE
Memory: 1 x HPE 32GB (1x32GB) Single Rank x4 DDR4-3200 CAS-22-22-22 Registered Memory Kit
Network Controller: Broadcom BCM57416 Ethernet 10Gb 2-port BASE-T OCP3 Adapter for HPE
Raid Controller: Broadcom MegaRAID MR416i-a x16 Lanes 4GB Cache NVMe/SAS 12G Controller for HPE Gen10 Plus
Hard Drive: None included (24 SFF Chassis)
Optical Drive: Not included (Optical Drive options available)
PCI-Express Slots: 3 PCIe: x8/x16/x8
Power Supply: 1 x HPE 800W Flex Slot Platinum Hot Plug Low Halogen Power Supply Kit
Form Factor: Rack (2U)
Warranty : 3-year parts, 3-year labor, 3-year onsite support with next business day response.
HPE ProLiant DL385 Gen10 Plus v2 server |
|||
The HPE ProLiant DL385 Gen10 Plus v2 Server is redefining price/performance with the new math for virtualized compute. Powered by the latest AMD® EPYC® 7003 Series Processors , the HPE ProLiant DL385 Gen10 Plus v2 Server offers greater processing power, memory speeds up to 3200 MT/s. and data transfer rates with PCIe Gen4 capabilities.
This 2P, 2U server has been designed with flexibility while delivering a high core count and large memory footprint. Choose this purpose-built platform for virtualization, High Performance Compute and memory centric workloads. |
|||
|
|||
HPE ProLiant DL385 Gen10 Plus v2 8 SFF Server- Front View |
|||
1. |
Quick removal access panel |
7. |
USB 3.1 Gen1 |
2. |
Power On/Standby button and system power LED button |
8. |
Serial label pull tag |
3. |
Health LED |
9. |
Drive Bay 3. 8 SFF SAS/SATA shown (Box 3) 1 |
4. |
NIC Status |
10. |
Drive Bay 2. Blank shown (Box 2) 2 |
5. |
Unit ID button |
11. |
Drive Bay 1. Blank shown (Box 1) 3 |
6. |
iLO front service port |
|
|
Notes: - 18 SFF U.2/U.3 optional - 28 SFF SAS/SATA or 8 SFF U.2/U.3 optional - 38 SFF SAS/SATA or 8 SFF U.2/U.3 or Universal Media Bay optional |
HPE ProLiant DL385 Gen10 Plus v2 Server - Rear View |
|||
1. |
Primary Riser. PCIe Slots1 |
8. |
HPE Flexible Slot power supply bay 2 |
2. |
Optional Secondary Riser. PCIe Slots2 |
9. |
VGA connector |
3. |
Tertiary Riser. PCIe Slots3 |
10. |
OCP 3.0 Slot |
4. |
Optional serial port (not shown) |
11. |
Unit ID LED |
5. |
Power supply power LED |
12. |
USB connectors 3.1 Gen1 (2) |
6. |
Power supply power connection |
13. |
Dedicated iLO management port |
7. |
HPE Flexible Slot Power Supply bay 1 |
|
|
Notes: - 1 Slots 1-3 top to bottom, riser shipped standard, not shown. - 2 Slots 4-6 top to bottom, not shown, requires second riser card, and second processor. Optional 2 SFF rear drives. - 3 Slots 7-8 top to bottom, not shown. Optional 2 SFF rear drives. |
|
|||
HPE ProLiant DL385 Gen10 Plus v2 Server - Internal View |
|||
1. |
2 Processors (heat sinks shown) |
7. |
OCP 3.0 Slot |
2. |
Internal USB 3.1 Gen1 connector |
8. |
Primary PCIe riser, standard (optional double wide GPU riser) |
3. |
Chassis intrusion detection connector |
9. |
DDR4 DIMM slots. Shown fully populated in 32 slots (16 per processor) |
4. |
Hot Plug redundant HPE Flexible Slot Power supplies |
10. |
Fan cage shown with 6 standard Hot-plug fans (high performance fans optional) |
5. |
Connection for second (optional) riser (requires second CPU) |
11. |
Optional Smart Storage Battery location (Battery not shown) |
6. |
Optional HPE Flexible Smart Array Controller (Type -a shown) |
|
|
What’s New:
https://www.hpe.com/us/en/about/environment/msds-specs-more.html for more information |
|||
|
Platform Information
Form Factor
|
|
Chassis Types
Notes: - DL385 Gen10 Plus v2 uses Basic Carrier drive cages, not Smart Carrier drive cages as used on DL385 Gen10 Plus. - The 4 LFF rear drive box will consume space for the primary and secondary riser. - The 8 and 12 LFF chassis also supports the 2 SFF rear drive box which allows for the user to attach a secondary or tertiary riser. - The 24 SFF chassis already supports 3x 8 SFF SAS/SATA drive cage kits - The 8 NVMe U.3 or U.2 cage kits (P27194-B21, P26931-B21, P26932-B21) can only be leveraged in the SFF chassis and replaces Box 1, 2 or 3. - The Universal Media Bay (P14609-B21) not available with the LFF chassis or the 24 SFF front, and can only be populated in Box 1. - The 8 NVMe SFF can be upgraded with additional two front 8 NVMe SFF U.3 or U.2 drive boxes (P27194-B21, P26931-B21, P26932-B21) to total 24 SFF NVMe drives, and up to 32 SFF NVMe drives with one mid 8 NVMe SFF mid-tray drive cage (P39600-B21, P38847-B21). U.3 and U.2 front and mid drive cages cannot mix. - U.3 x1 and x4 drive cages cannot mix. - The 8 LFF chassis cannot be upgraded to 12 LFF front in the field. - 12 LFF or more drives require Max performance fan kit (P14608-B21). - CPU selection is limited 225W (Turbo to 240W) or lower with 4LFF mid-tray selected & DIMM blanks populate empty DIMM slots. |
|
System Fans Standard – fan types included
|
|
Processors Up to 2 of the following depending on model. Notes: For more information regarding AMD EPYC processors, please see the following: https://www.amd.com/en/products/epyc |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Notes: All AMD EPYC processors can support up to 4TB of memory each |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Chipset No chipset – System on Chip (SoC) design. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
On System Management Chipset HPE iLO 5 ASIC
Read and learn more in the iLO QuickSpecs. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Memory One of the following depending on model |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Notes: - The maximum memory speed is limited by the processor selection. - 3200 MT/s memory SKUs can run the transfer rate of 3200 MT/s at both 1 DIMM and 2 DIMM per channel, except 256 GB LRDIMM |
Memory Protection Advanced ECC Advanced ECC uses single device data correction to detect and correct single and all multibit error that occurs within a single DRAM chip. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Expansion Slots
Primary Riser Notes: - Bus width indicates the number of physical electrical lanes running to the connector. - There are 3 types of risers supported on Primary Slot - When supporting Slot1 & Slot2 in below Primary Riser3 scenario, Slot1 & Slot2 combined can support up to 38GB/s bandwidth, due to an AMD CPU limitation. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Notes: ** Default Slot1 on the Primary Riser3 is empty and not available. It requires P14600-B21 in conjunction with the Primary Riser3 to add additional x16 PCIe Gen4 in slot1. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Secondary Riser: Notes: - Bus Width Indicates the number of physical electrical lanes running to the connector. - There are 3 types of risers support on Secondary Slot |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||
Notes: * Default Slot4 on the Secondary Riser3 is empty and not available.It requires P14600-B21 in conjunction with the Secondary Riser3 to add additional x16 PCIe Gen4 in slot4 |
||||||||||||||||||||||||||||||||||||
Tertiary Riser: Notes: - Bus Width Indicates the number of physical electrical lanes running to the connector. - There are 2 types of risers support on Tertiary Slot |
||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||
Storage Controllers The Gen10/Gen10 Plus controller naming framework has been updated to simplify identification as depicted below. For a more detailed breakout of the available Gen10/Gen10 Plus Smart Array controllers visit the HPE Smart Array Gen10 Controllers Data Sheet.
HPE also launched Tri-Mode controllers which will support NVMe U.3/U.2 drives as wells as SAS/SATA drives. Please see below list for the tri-mode controllers supported on the server.
One of the following depending on model |
||||||||||||||||||||||||||||||||||||
NVMe Boot Device
Notes: - NS204i-p will only be supported in Slot 1 of the primary riser. - NS204i-p and Primary Riser HPE DL38X Gen10+ 2x16 Slot 2/3 FIO Kit (P14599-B21) are selected then HPE DL38X Gen10+ Slot1 x16 Slot2/3 Kit (P14600-B21) also must be in the configuration. - Legacy Mode setting (758959-B21) and NS204i-p cannot be selected together. - HPE Universal SATA AIC HHHL M.2 SSD Kit (878783-B21) and NS204i-p cannot be selected together. - When NS204i-p and doublewide GPU are selected together Secondary Riser MUST be selected and doublewide GPU can be maximum of 2. |
||||||||||||||||||||||||||||||||||||
Software RAID – HPE Smart Storage SR100i SR Gen10 Plus SW RAID
|
||||||||||||||||||||||||||||||||||||
Essential RAID Controller
|
||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||
Performance RAID Controller
Notes: Performance RAID Controllers require the HPE Smart Storage Battery (P01366-B21) which is sold separately. |
||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||
Tri-Mode RAID Controller
|
||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||
Internal Storage Devices One of the following depending on model
Optical Drive
Hard Drives
|
||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||
Graphics
Integrated Video Standard
HPE iLO 5 on system management memory
|
||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||
Power Supply
Notes: Available in 94% Power Efficiency.
Notes: Available in 94%. Power Efficiency
Notes: - Available in 96% Power Efficiency - 200-240VAC power input only.
Notes: - Available in 94% Power Efficiency - 277VAC power input.
Notes: - Available in 94% Power Efficiency - -48VDC power input.
Notes: - Available in 94% Power Efficiency. - 200-240VAC power input only.
|
||||||||||||||||||||||||||||
HPE Flexible Slot (Flex Slot) Power Supplies share a common electrical and physical design that allows for hot plug, tool-less installation into HPE ProLiant Gen10 Plus Performance Servers. Flex Slot power supplies are certified for high-efficiency operation and offer multiple power output options, allowing users to "right-size" a power supply for specific server configurations. This flexibility helps to reduce power waste, lower overall energy costs, and avoid "trapped" power capacity in the data center. All pre-configured servers ship with a standard 6-foot IEC C-13/C-14 jumper cord (A0K02A). This jumper cord is also included with each standard AC power supply option kit. If a different power cord is required, please check the ProLiant Power Cables web page.
To review the power requirements for your selected system, please use the HPE Power Advisor Tool.
For information on power specifications and technical content visit HPE Server power supplies. |
||||||||||||||||||||||||||||
|
Interfaces
|
||||||||||||||||
Notes: Not shipping as standard. Available as a CTO option or as a field upgrade (P14611-B21). |
||||||||||||||||
|
||||||||||||||||
UEFI Configure and boot your servers securely with industry standard Unified Extensible Firmware Interface (UEFI).
Learn more at http://www.hpe.com/servers/uefi. |
||||||||||||||||
|
||||||||||||||||
Operating Systems and Virtualization Software Support for ProLiant Servers
Notes: For more information on Hewlett Packard Enterprise Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server. https://www.hpe.com/us/en/servers/server-operating-systems.html |
||||||||||||||||
|
||||||||||||||||
HPE Server UEFI/Legacy ROM Unified Extensible Firmware Interface (UEFI) is an industry standard that provides better manageability and more secured configuration than the legacy ROM while interacting with your server at boot time. HPE ProLiant Gen10 Plus servers have a UEFI Class 2 implementation and support both UEFI Mode (default) and Legacy BIOS Mode. Notes: The UEFI System Utilities tool is analogous to the HPE ROM-Based Setup Utility (RBSU) of legacy BIOS. For more information, please visit http://www.hpe.com/servers/uefi.
UEFI enables numerous new capabilities specific to HPE ProLiant servers such as
|
||||||||||||||||
HPE Server UEFI/Legacy ROM
UEFI Boot Mode only
Notes: For UEFI Boot Mode, boot environment and OS image installations should be configured properly to support UEFI. |
||||||||||||||||
|
||||||||||||||||
Industry Standard Compliance
Notes: This support is on the optional Universal Media Bay.
Notes: This support is on the optional Universal Media Bay.
|
||||||||||||||||
https://www.hpe.com/us/en/about/environment/msds-specs-more.html
Notes: For additional technical thermal details regarding ambient temperatures, humidity and features support please visit: http://www.hpe.com/servers/ashrae.
|
||||||||||||||||
|
Embedded Management
HPE Integrated Lights-Out (HPE iLO) Monitor your servers for ongoing management, service alerting, reporting and remote management with HPE iLO. Learn more at http://www.hpe.com/info/ilo. |
|
Intelligent Provisioning Hassle free server and OS provisioning for 1 or more servers with Intelligent Provisioning. Learn more at http://www.hpe.com/servers/intelligentprovisioning. |
|
iLO RESTful API iLO RESTful API is Redfish API conformance and offers simplified server management automation such as configuration and maintenance tasks based on modern industry standards. Learn more at http://www.hpe.com/info/restfulapi. |
|
Server Utilities
Active Health System The HPE Active Health System (AHS) is an essential component of the iLO management portfolio that provides continuous, proactive health monitoring of HPE servers. Learn more at http://www.hpe.com/servers/ahs. |
|
Active Health System Viewer Use the Active Health System Viewer, a web-based portal, to easily read AHS logs and speed problem resolution with HPE self-repair recommendations, to learn more visit: http://www.hpe.com/servers/ahsv. |
|
Smart Update Keep your servers up to date with the HPE Smart Update solution by using Smart Update Manager (SUM) to optimize the firmware and driver updates of the Service Pack for ProLiant (SPP). Learn more at https://www.hpe.com/us/en/servers/smart-update.html . |
|
iLO Amplifier Pack Designed for large enterprise and service provider environments with hundreds of HPE servers, the iLO Amplifier Pack is a free, downloadable open virtual application (OVA) that delivers the power to discover, inventory and update Gen8, Gen9 , Gen10 & Gen10 Plus HPE servers at unmatched speed and scale. Use with an iLO Advanced License to unlock full capabilities. Learn more at http://www.hpe.com/servers/iLOamplifierpack. |
|
HPE iLO Mobile Application Enables the ability to access, deploy, and manage your server anytime from anywhere from select smartphones and mobile devices. For additional information please visit: http://www.hpe.com/info/ilo/mobileapp. |
|
RESTful Interface Tool RESTful Interface tool (iLOREST) is a single scripting tool to provision using iLO RESTful API to discover and deploy servers at scale. Learn more at http://www.hpe.com/info/resttool. |
|
Scripting Tools Provision one to many servers using your own scripts to discover and deploy with Scripting Tool (STK) for Windows and Linux or Scripting Tools for Windows PowerShell. Learn more at http://www.hpe.com/servers/powershell. |
|
HPE OneView Standard HPE OneView Standard can be used for inventory, health monitoring, alerting, and reporting without additional fees. It can monitor multiple HPE server generations. The user interface is similar to the HPE OneView Advanced version, but the software-defined functionality is not available. Learn more at http://www.hpe.com/info/oneview. |
HPE Systems Insight Manager (HPE SIM) Ideal for environments already using HPE SIM, it allows you to monitor the health of your HPE ProLiant Servers and HPE Integrity Servers. Also provides you with basic support for non-HPE servers. HPE SIM also integrates with Smart Update Manager to provide quick and seamless firmware updates. Learn more at http://www.hpe.com/info/hpesim. |
|
Warranty This product is covered by a global limited warranty and supported by HPE Services and a worldwide network of Hewlett Packard Enterprise Authorized Channel Partners resellers. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Enhancements to warranty services are available through HPE Pointnext operational services or customized service agreements. Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details.
Notes: Server Warranty includes 3-Year Parts, 3-Year Labor, 3-Year Onsite support with next business day response. Warranty repairs may be accomplished through the use of Customer Self Repair (CSR) parts. These parts fall into two categories: 1) Mandatory CSR parts are designed for easy replacement. A travel and labor charge will result when customers decline to replace a Mandatory CSR part; 2) Optional CSR parts are also designed for easy replacement but may involve added complexity. Customers may choose to have Hewlett Packard Enterprise replace Optional CSR parts at no charge. Additional information regarding worldwide limited warranty and technical support is available at: http://h17007.www1.hpe.com/us/en/enterprise/servers/warranty/. |
|
Security
|